{"title":"Pump Groups \u0026 Manifolds","description":"\u003cp\u003eOur pump groups for heating systems combine reliable pumping performance, energy efficiency, and easy integration into modern heating circuits. They are designed for reliable operation in residential, commercial, and industrial facilities and support optimal heat distribution in radiators, underfloor heating, and heat pump systems.\u003c\/p\u003e\n\u003cp\u003eAdvantages:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEnergy-efficient pumping technology with integrated control\u003c\/li\u003e\n\u003cli\u003eContinuously adjustable circulation pumps for demand-oriented heating output\u003c\/li\u003e\n\u003cli\u003eCompact design, easy installation, and maintenance\u003c\/li\u003e\n\u003cli\u003eCorrosion-resistant materials and long service life\u003c\/li\u003e\n\u003cli\u003eLow noise and low vibration during operation\u003c\/li\u003e\n\u003cli\u003eIntelligent control (e.g., via building technology, mixer and heating circuit control)\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"pumpengruppe-hydra-gpo-s-pumpengruppe-fur-zentralheizung-dreiwege-mischventil-mit-servomotor","title":"Pump group for central heating - with three-way mixing valve with servo motor - Hydra GPO S DN 20","description":"\u003ch2\u003e Hydra GPO S DN 20 pump group - pump group for central heating - with three-way mixing valve with servo motor\u003c\/h2\u003e\n\n\u003cp\u003e The pump unit with a three-way mixing valve is used to force the circulation of the working fluid in central heating, process heating, and cooling systems. Motor cover made of BMC. The circulation pump allows operation in: Δp-c, Δp-v, constant speed, and AUTO adjustment mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n\u003ch2\u003e Equipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Hydra circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Three-way mixing valve with servo motor\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch2\u003e COMPACT HEATING CIRCUIT STATION DN20\u003c\/h2\u003e\n\n\u003cp\u003e \u003cstrong\u003eSUNEX Hydra GPO S DN20\u003c\/strong\u003e pump group with Hydra circulation pump (130 mm)\u003cbr\u003e Intended use: compact heating circuit solutions in central heating systems, cooling systems or process heat applications\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e WITH 3-WAY MIXING VALVE \u0026amp; ACTUATOR\u003c\/h3\u003e\n\n \u003cp\u003e\u003cstrong\u003eMixing valve with servo motor\u003c\/strong\u003e (6 Nm, opening time 120 s)\u003cbr\u003e Flow rate KVS 5.3\u003cbr\u003e Suitable for low-temperature systems or underfloor heating.\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e EASY TO INSTALL\u003c\/h3\u003e\n\n\u003cp\u003e Upper connections IG ¾″, lower connections AG 1″\u003cbr\u003e Ball valves with integrated check valve\u003cbr\u003e Thermometer (blue return, red supply)\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e EFFICIENT CIRCULATION PUMP\u003c\/h3\u003e\n\n\u003cp\u003e Hydra GPO 20-6-130\u003cbr\u003e AUTOADAPT, Δp-c, Δp-v and constant speed\u003cbr\u003e Power consumption up to 65 W, EEI ≤ 0.20\u003cbr\u003e Energy-saving, quiet operation\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e TECHNICAL DETAILS\u003c\/h3\u003e\n\n\u003cp\u003e Max. pressure: 6 bar, Max. temperature: 90 °C\u003cbr\u003e Dimensions: 390 × 275 × 140 mm\u003cbr\u003e Weight: 6.5 kg\u003cbr\u003e Connection spacing: 125 mm\u003cbr\u003e Areas of application: Single-family homes, renovations, space-saving technical centers \u003cbr\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOS_600x600.jpg?v=1764687659\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/HydraGPOStechischeDaten_600x600.jpg?v=1764687659\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Hydra_GPO_S_hydraulische_Eigenschaften_600x600.jpg?v=1764757738\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47115490820288,"sku":"400011737","price":279.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOS_1.jpg?v=1764687870"},{"product_id":"pumpengruppe-fur-zentralheizung-mit-dreiwege-mischventil-mit-servomotor-hydra-gpo-s-dn-25","title":"Pump group for central heating - with three-way mixing valve with servo motor - Hydra GPO S DN 25","description":"\u003ch2\u003e Hydra GPO S DN 25 pump group - pump group for central heating - with three-way mixing valve with servo motor\u003c\/h2\u003e\n\n\u003cp\u003e The pump unit with a three-way mixing valve is used to force the circulation of the working fluid in central heating, process heating, and cooling systems. Motor cover made of BMC. The circulation pump allows operation in: Δp-c, Δp-v, constant speed, and AUTO adjustment mode.\u003c\/p\u003e\n\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\n \u003ch2\u003eEquipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Hydra circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Three-way mixing valve with servo motor\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch2\u003e COMPACT HEATING CIRCUIT STATION DN25\u003c\/h2\u003e\n\n\u003cp\u003e \u003cstrong\u003eSUNEX Hydra GPO S DN25\u003c\/strong\u003e pump group with Hydra circulation pump (130 mm)\u003cbr\u003e Intended use: compact heating circuit solutions in central heating systems, cooling systems or process heat applications\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e WITH 3-WAY MIXING VALVE \u0026amp; ACTUATOR\u003c\/h3\u003e\n\n\u003cp\u003e \u003cstrong\u003eMixing valve with servo motor\u003c\/strong\u003e (6 Nm, opening time 120 s)\u003cbr\u003e Flow rate KVS 8\u003cbr\u003e Suitable for low-temperature systems or underfloor heating.\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e EASY TO INSTALL\u003c\/h3\u003e\n\n\u003cp\u003e Upper connections IG 1″, lower connections AG 1½”\u003cbr\u003e Ball valves with integrated check valve\u003cbr\u003e Thermometer (blue return, red supply)\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e EFFICIENT CIRCULATION PUMP\u003c\/h3\u003e\n\n\u003cp\u003e Hydra GPO 25-6-130\u003cbr\u003e AUTOADAPT, Δp-c, Δp-v and constant speed\u003cbr\u003e Power consumption up to 65 W, EEI ≤ 0.20\u003cbr\u003e Energy-saving, quiet operation\u003c\/p\u003e\n\n\u003ch3\u003e\n\n\u003cbr\u003e TECHNICAL DETAILS\u003c\/h3\u003e\n\n\u003cp\u003e Max. pressure: 6 bar, Max. temperature: 90 °C \u003cbr\u003eDimensions: 390 × 275 × 140 mm\u003cbr\u003e Weight: 6.9 kg\u003cbr\u003e Connection spacing: 125 mm\u003cbr\u003e Areas of application: Single-family homes, renovations, space-saving technical centers \u003cbr\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOS_600x600.jpg?v=1764687659\" alt=\"\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/HydraGPOStechischeDaten_600x600.jpg?v=1764687659\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"float: none;\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Hydra_GPO_S_hydraulische_Eigenschaften_600x600.jpg?v=1764757738\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47118775779520,"sku":"400011733","price":289.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOS_1.jpg?v=1764687870"},{"product_id":"zweiwege-pumpengruppe-heizkreisset-ohne-mischventil-zweiwege-hydra-gpo","title":"Two-way pump group - heating circuit set without mixing valve - Two-way Hydra GPO DN 20","description":"\u003ch2\u003e Hydra GPO DN 20 pump group - Pump group for central heating - Two-way without mixing valve\u003c\/h2\u003e\n\n \u003cp\u003eThe pump unit is used to force the circulation of the working fluid in central heating, process heat, and cooling systems. Motor cover made of BMC. The circulation pump allows operation in: Δp-c, Δp-v, constant speed, and AUTO adjustment mode.\u003c\/p\u003e\n\n\u003ch2\u003e Equipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the flow line\u003c\/li\u003e\n\n\u003cli\u003e Hydra circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation.\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e COMPACT HEATING CIRCUIT STATION\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e The \u003cstrong\u003eSUNEX Hydra GPO DN20\u003c\/strong\u003e is a pre-assembled two-way pump group with Hydra circulation pump (130 mm) – ideal for smaller heating and cooling systems in residential buildings or technical centers.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e TWO-WAY SYSTEM WITH THERMOMETERS\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e Two ball valves with integrated thermometers (blue return, red supply with check valve) enable precise control and safe separation of supply and return.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e ENERGY-SAVING PUMP\u003c\/h3\u003e\n\n \u003cdiv style=\"text-align: start;\"\u003eThe Hydra GPO 20-6-130 supports AUTOADAPT, Δp-c, Δp-v and constant speed – maximum power consumption 65 W, EEI ≤ 0.20 – efficient operation with long service life.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e EASY TO INSTALL \u0026amp; INSULATED\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e With connection dimensions of IG ¾″ (top) and AG 1″ (bottom), the station can be installed quickly. The integrated thermal insulation reliably protects against unnecessary heat loss.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e TECHNICAL DETAILS\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e Max. pressure: 6 bar, Max. temperature: 90 °C, Dimensions: 390×275×140 mm, Connection spacing: 125 mm, Weight: 5.0 kg – ideal for low-temperature applications or efficient radiator heating. \u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOohnemischventil_4_600x600.jpg?v=1764767330\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOtechnischeDaten_600x600.jpg?v=1764767330\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOhydraulischeEigenschaften.jpg?v=1764767330\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47118880342208,"sku":"400011735","price":229.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOohnemischventil.jpg?v=1764767330"},{"product_id":"zweiwege-pumpengruppe-heizkreisset-ohne-mischventil-zweiwege-hydra-gpo-dn-25","title":"Two-way pump group - heating circuit set without mixing valve - Two-way Hydra GPO DN 25","description":"\u003ch2\u003e Hydra GPO DN 25 pump group - Pump group for central heating - Two-way without mixing valve\u003c\/h2\u003e\n\n\u003cp\u003e The pump unit is used to force the circulation of the working fluid in central heating, process heat, and cooling systems. Motor cover made of BMC. The circulation pump allows operation in: Δp-c, Δp-v, constant speed, and AUTO adjustment mode.\u003c\/p\u003e\n\n\u003ch2\u003e Equipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n \u003cli\u003etwo ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Hydra circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation.\u003cbr\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e COMPACT HEATING CIRCUIT STATION\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e The \u003cstrong\u003eSUNEX Hydra GPO DN25\u003c\/strong\u003e is a pre-assembled two-way pump group with Hydra circulation pump (130 mm) – ideal for smaller heating and cooling systems in residential buildings or technical centers.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e TWO-WAY SYSTEM WITH THERMOMETERS\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e Two ball valves with integrated thermometers (blue return, red supply with check valve) enable precise control and safe separation of supply and return.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e ENERGY-SAVING PUMP\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e The Hydra GPO 25-6-130 supports AUTOADAPT, Δp-c, Δp-v and constant speed – maximum power consumption 65 W, EEI ≤ 0.20 – efficient operation with long service life.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n\u003cbr\u003e EASY TO INSTALL \u0026amp; INSULATED\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e With connection dimensions of 1\" internal thread (top) and 1.5\" external thread (bottom), the station can be installed quickly. The integrated thermal insulation reliably protects against unnecessary heat loss.\u003c\/div\u003e\n\n\u003ch3 style=\"text-align: start;\"\u003e\n\n \u003cbr\u003eTECHNICAL DETAILS\u003c\/h3\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e Max. pressure: 6 bar, Max. temperature: 90 °C, Dimensions: 390×275×140 mm, Connection spacing: 125 mm, Weight: 5.3 kg – ideal for low-temperature applications or efficient radiator heating. \u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOohnemischventil_4_600x600.jpg?v=1764767330\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOtechnischeDaten_600x600.jpg?v=1764767330\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOhydraulischeEigenschaften.jpg?v=1764767330\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47118989328576,"sku":"400011731","price":239.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeHydraGPOohnemischventil.jpg?v=1764767330"},{"product_id":"pumpengruppe-fur-zentralheizung-zweiwege-gpo-wilo-dn-20","title":"Pump group for central heating - two-way without mixing valve - GPO Wilo DN 20","description":"\u003ch2\u003e Wilo GPO DN 20 pump group - Pump group for central heating - Two-way without mixing valve - Wilo circulation pump\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e \u003cbr\u003eThe pump group serves to force the circulation of the working fluid in the central heating, process heat, and cooling system. The circulation pumps allow operation in: Δp-c, Δp-v, and constant speed conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch2\u003e Equipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cimg style=\"float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/GPOWiloDN20_3_600x600.jpg?v=1764939661\"\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2 style=\"text-align: start;\"\u003e Characteristics:\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Removable housing insulation\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC 25\/6 high-efficiency pump (constant speed in 3 stages) 130mm installation length\u003c\/li\u003e\n\n\u003cli\u003e Red supply line: Thermometer (0-160°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli\u003e Return line (blue): Thermometer (0-100°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli\u003e Connections at the top: DN20 = 2x IG 3\/4\" \/ DN25 = 2x IG 1\"\u003c\/li\u003e\n\n\u003cli\u003e Connections at the bottom: DN20 = 2x AG 1\" \/ DN25 = 2x AG 1 1\/2\"\u003c\/li\u003e\n\n\u003cli\u003e Distance between flow and return pipes: 125 mm\u003c\/li\u003e\n\n\u003cli\u003e Pressure: max. 6 bar\u003c\/li\u003e\n\n\u003cli\u003e Temperature: max. 90°C\u003c\/li\u003e\n\n\u003cli\u003e Dimensions: 390 x 275 x 140 mm (H x W x D)\u003c\/li\u003e\n\n\u003cli\u003e Weight: DN20 = 5 kg \/ DN25 = 5.3 kg\u003c\/li\u003e\n\n\u003cli\u003e 230V\/ 50 Hz \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/TechnischeDatenGPOWiloDN20-25_600x600.jpg?v=1764939661\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47119036809408,"sku":"400011719","price":245.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeGPOWiloDN20_1.jpg?v=1764939661"},{"product_id":"pumpengruppe-fur-zentralheizung-zweiwege-ohne-mischventil-gpo-wilo-dn-25","title":"Pump group for central heating - two-way without mixing valve - GPO Wilo DN 25","description":"\u003ch2\u003e Wilo GPO DN 25 pump group - Pump group for central heating - Two-way without mixing valve - Wilo circulation pump\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e\u003cbr\u003e The pump group serves to force the circulation of the working fluid in the central heating, process heat, and cooling system. The circulation pumps allow operation in: Δp-c, Δp-v, and constant speed conditions.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch2\u003e Equipment of the pump group:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n \u003cli\u003etwo ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/GPOWiloDN20_3_600x600.jpg?v=1764939661\" style=\"float: none;\"\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003ch2 style=\"text-align: start;\"\u003e Characteristics:\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e Removable housing insulation\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC 25\/6 high-efficiency pump (constant speed in 3 stages) 130mm installation length\u003c\/li\u003e\n\n\u003cli\u003e Red supply line: Thermometer (0-160°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli\u003e Return line (blue): Thermometer (0-100°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli\u003e Connections at the top: DN20 = 2x IG 3\/4\" \/ DN25 = 2x IG 1\"\u003c\/li\u003e\n\n\u003cli\u003e Connections at the bottom: DN20 = 2x AG 1\" \/ DN25 = 2x AG 1 1\/2\"\u003c\/li\u003e\n\n\u003cli\u003e Distance between flow and return pipes: 125 mm\u003c\/li\u003e\n\n\u003cli\u003e Pressure: max. 6 bar\u003c\/li\u003e\n\n\u003cli\u003e Temperature: max. 90°C\u003c\/li\u003e\n\n\u003cli\u003e Dimensions: 390 x 275 x 140 mm (H x W x D)\u003c\/li\u003e\n\n\u003cli\u003e Weight: DN20 = 5 kg \/ DN25 = 5.3 kg\u003c\/li\u003e\n\n\u003cli\u003e 230V\/ 50 Hz \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/TechnischeDatenGPOWiloDN20-25_600x600.jpg?v=1764939661\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47125504327872,"sku":"400011718","price":255.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeGPOWiloDN20_1.jpg?v=1764939661"},{"product_id":"pumpengruppe-fur-zentralheizung-mit-dreiwege-mischventil-mit-servomotor-wilo-gpo-s-dn-20","title":"Pump group for central heating - with three-way mixing valve with servo motor - Wilo GPO S DN 20","description":"\u003ch2\u003e Wilo GPO S DN 20 pump group - pump group for central heating - with three-way mixing valve with servo motor - Wilo circulation pump\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e The pump assembly with a three-way mixing valve is used to force the circulation of the working fluid in the central heating, process heat, and cooling system. The circulation pump allows operation in: Δp-c, Δp-v, and constant speed modes.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\n\u003ch2\u003e Equipment of the pump group\u003c\/h2\u003e\n\n\u003cul\u003e\n\n \u003cli\u003etwo ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Three-way mixing valve with servo motor\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeWiloGPOSDN20_3_600x600.jpg?v=1764942832\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003ch2 style=\"text-align: start;\"\u003e Characteristics:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Removable housing insulation\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Wilo Para SC 25\/6 high-efficiency pump (constant speed in 3 stages) 130mm installation length\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e 3-way mixer with actuator\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Red supply line: Thermometer (0-160°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Return line (blue): Thermometer (0-100°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Connections at the top: DN20 = 2x IG 3\/4\" \/ DN25 = 2x IG 1\"\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Connections at the bottom: DN20 = 2x AG 1\" \/ DN25 = 2x AG 1 1\/2\"\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Distance between flow and return pipes: 125 mm\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Pressure: max. 6 bar\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Temperature: max. 90°C\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Dimensions: 390 x 275 x 140 mm (H x W x D)\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Weight: DN20 = 6.5 kg \/ DN25 = 6.9 kg\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e 230V\/ 50 Hz \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/technischeDatenWiloGPOSDN20-25_600x600.jpg?v=1764942832\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47125521301696,"sku":"400011757","price":289.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeWiloGPOSDN20_1.jpg?v=1764942832"},{"product_id":"pumpengruppe-fur-zentralheizung-mit-dreiwege-mischventil-mit-servomotor-wilo-gpo-s-dn-25","title":"Pump group for central heating - with three-way mixing valve with servo motor - Wilo GPO S DN 25","description":"\u003ch2\u003e Wilo GPO S DN 25 pump group - pump group for central heating - with three-way mixing valve with servo motor - Wilo circulation pump\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n \u003cp\u003eThe pump assembly with a three-way mixing valve is used to force the circulation of the working fluid in the central heating, process heat, and cooling system. The circulation pump allows operation in: Δp-c, Δp-v, and constant speed modes.\u003c\/p\u003e\n\n\u003ch2\u003e\u003cbr\u003e\u003c\/h2\u003e\n\n\u003ch2\u003e Equipment of the pump group\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Wilo Para SC circulation pump with 130 mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Three-way mixing valve with servo motor\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation. \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeWiloGPOSDN20_3_600x600.jpg?v=1764942832\"\u003e\u003c\/div\u003e\n\n\u003ch2 style=\"text-align: start;\"\u003e Characteristics:\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Removable housing insulation\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Wilo Para SC 25\/6 high-efficiency pump (constant speed in 3 stages) 130mm installation length\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e 3-way mixer with actuator\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Red supply line: Thermometer (0-160°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Return line (blue): Thermometer (0-100°C) with ball valve and check valve\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Connections at the top: DN20 = 2x IG 3\/4\" \/ DN25 = 2x IG 1\"\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Connections at the bottom: DN20 = 2x AG 1\" \/ DN25 = 2x AG 1 1\/2\"\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Distance between flow and return pipes: 125 mm\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Pressure: max. 6 bar\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Temperature: max. 90°C\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Dimensions: 390 x 275 x 140 mm (H x W x D)\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e Weight: DN20 = 6.5 kg \/ DN25 = 6.9 kg\u003c\/li\u003e\n\n\u003cli style=\"text-align: start;\"\u003e 230V\/ 50 Hz \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/technischeDatenWiloGPOSDN20-25_600x600.jpg?v=1764942832\"\u003e\u003c\/div\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47125550235840,"sku":"400011756","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeWiloGPOSDN20_1.jpg?v=1764942832"},{"product_id":"zweiwege-pumpengruppe-heizkreisset-ohne-mischventil-zweiwege-gpo-grundfos-dn-25","title":"Two-way pump group - heating circuit set without mixing valve - two-way GPO Grundfos DN 25","description":"\u003ch2\u003e Grundfos GPO DN 25 pump group - Pump group for central heating - Two-way without mixing valve - Grundfos circulation pump \u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e The pump group serves to circulate the working fluid.\u003cbr\u003e media in central heating, process heat and \u003cbr\u003eTo force the cooling system.\u003cbr\u003e The circulation pump enables operation in the following operating modes:\u003cbr\u003e Δp-c, Δp-v, constant rotational speed.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\n\n\u003ch2\u003e equipment\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Grundfos UPM3S Auto 25-60 circulation pump with 130mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation \u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeGPOGrundfosDN25_3_600x600.jpg?v=1764946357\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47125655748800,"sku":"400011724","price":259.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumpengruppeGPOGrundfosDN25_1.jpg?v=1764946357"},{"product_id":"pumpengruppe-fur-zentralheizung-mit-dreiwege-mischventil-mit-servomotor-gpo-s-grundfos-dn-25","title":"Pump group for central heating - with three-way mixing valve with servo motor - GPO S Grundfos DN 25","description":"\u003ch2\u003eGrundfos GPO S DN 25 pump group - pump group for central heating - with three-way mixing valve with servo motor - Grundfos circulation pump \u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e The pump group with three-way mixing valve is used for the forced circulation of the working medium in central heating, process heat and cooling.\u003cbr\u003e The circulation pump allows operation in the following modes: Δp-c, Δp-v, constant speed.\u003c\/p\u003e\n\n\u003ch2\u003e\n\n\u003cbr\u003e Equipment of the pump group\u003c\/h2\u003e\n\n\u003cul\u003e\n\n\u003cli\u003e two ball valves with integrated thermometers\u003cbr\u003e and a check valve on the supply line\u003c\/li\u003e\n\n\u003cli\u003e Grundfos UPM3S Auto 25-60 circulation pump with 130mm spacing\u003c\/li\u003e\n\n\u003cli\u003e Three-way mixing valve with actuator\u003c\/li\u003e\n\n\u003cli\u003e Thermal insulation \u003cbr\u003e\n\n\u003c\/li\u003e\n\n\n\u003c\/ul\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumepngruppeGPOSGrundfosDN25_4_600x600.jpg?v=1764947570\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/technischeDatenGPOSGrundfosDN25_600x600.jpg?v=1764947570\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp\u003e\u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47125763227840,"sku":"400011726","price":299.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/PumepngruppeGPOSGrundfosDN25_1.jpg?v=1764947570"},{"product_id":"heizkreisverteilerbalken-fur-2-kreise-hydraulische-weiche-verteiler-sunex-2gpo-dn25-125mm","title":"Heating circuit manifold for 2 circuits - DN25 manifold for pump groups - Sunex 2GPO DN25 125mm","description":"\u003ch2\u003e Heating circuit manifold for 2 circuits - DN25 manifold for pump groups in central heating systems with radiators, underfloor heating and hybrid systems - Sunex 2GPO DN25 125mm manifold\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e The distributors are designed for use in central heating systems with radiators, underfloor heating and mixing systems.\u003cbr\u003e The device allows the distribution of heating water to two or three independent circuits. The mounting system enables quick and easy installation of the manifold on the wall. \u003cbr\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Verteiler2GPODN25125mm_690006203_690007203__4_600x600.jpg?v=1765197720\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47130446790848,"sku":"690006203","price":149.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Verteiler2GPODN25125mm_690006203_690007203__1.webp?v=1765197720"},{"product_id":"heizkreisverteilerbalken-fur-3-kreise-verteilerbalken-dn25-fur-pumpengruppen-sunex-3gpo-dn25-125mm","title":"Heating circuit manifold for 3 circuits - DN25 manifold for pump groups - Sunex 3GPO DN25 125mm","description":"\u003ch2\u003e Heating circuit manifold for 3 circuits - DN25 manifold for pump groups in central heating systems with radiators, underfloor heating and hybrid systems - Sunex 3GPO DN25 125mm manifold\u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n \u003cdiv style=\"text-align: start;\"\u003eThe distributors are designed for use in central heating systems with radiators, underfloor heating and mixing systems.\u003cbr\u003e The device allows the distribution of heating water to two or three independent circuits. The mounting system enables quick and easy installation of the manifold on the wall. \u003cbr\u003e\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Verteiler_2GPO_DN25_125mm_690006203_690007203__5_600x600.jpg?v=1765198995\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47130488537280,"sku":"690007203","price":179.95,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/Verteiler_3GPO_DN25_125mm_690006203_690007203__1.webp?v=1765198995"},{"product_id":"hydraulische-weiche-dn25-zur-trennung-des-warme-quellenkreises-und-des-heizkreises","title":"Hydraulic separator DN25 for separating the heat source circuit and the heating circuit","description":"\u003ch2\u003e Hydraulic separator DN25 for separating the heat source circuit and the heating circuit \u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n\u003cp\u003e The hydraulic separator serves to separate the heat source circuit and the heating circuit. It ensures the independent operation of both circuits without the need for flow balancing.\u003c\/p\u003e\n\n\u003cp\u003e The diverter valve is empty inside, allowing flow in all directions depending on the operating mode of the heating system. It also enables flushing and venting of the heating medium. \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/technischeDatenHydraulischeWeicheDN25_600x600.jpg?v=1765200874\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/AbmessungenHydraulischeWeicheDN25_600x600.jpg?v=1765200874\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n \u003cp class=\"MsoNoSpacing\"\u003e\u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47130544996544,"sku":"690007301","price":119.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/HydraulischeWeicheDN25_1.jpg?v=1765200874"},{"product_id":"hydraulische-weiche-dn32-zur-trennung-des-warme-quellenkreises-und-des-heizkreises","title":"Hydraulic separator DN32 for separating the heat source circuit and the heating circuit","description":"\u003ch2\u003e Hydraulic separator DN32 for separating the heat source circuit and the heating circuit \u003c\/h2\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\n\n \u003cp\u003eThe hydraulic separator serves to separate the heat source circuit and the heating circuit. It ensures the independent operation of both circuits without the need for flow balancing.\u003c\/p\u003e\n\n\u003cp\u003e The diverter valve is empty inside, allowing flow in all directions depending on the operating mode of the heating system. It also enables flushing and venting of the heating medium. \u003c\/p\u003e\n\n\u003cp\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/technischeDatenHydraulischeWeicheDN25_600x600.jpg?v=1765200874\"\u003e\u003c\/p\u003e\n\n\n\u003c\/div\u003e\n\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/AbmessungenHydraulischeWeicheDN25_600x600.jpg?v=1765200874\" style=\"margin-bottom: 16px; float: none;\"\u003e\u003c\/div\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eImportant NOTE!\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp class=\"MsoNoSpacing\"\u003e \u003cstrong\u003eThe installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.\u003c\/strong\u003e\u003c\/p\u003e\n\n\u003cp\u003e \u003cspan style=\"font-size: 12px;\"\u003eTechnical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.\u003c\/span\u003e\u003c\/p\u003e","brand":"Sunex","offers":[{"title":"Default Title","offer_id":47130602733760,"sku":"690007302","price":139.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0670\/5073\/3760\/files\/HydraulischeWeicheDN25_1.jpg?v=1765200874"}],"url":"https:\/\/klimango.de\/en\/collections\/pumpengruppen-verteiler.oembed","provider":"klimango","version":"1.0","type":"link"}