Sunex Heat Pump Complete Set 8 kW NEXUS M8 EVI Monoblock with Domestic Hot Water and Buffer Tank R32 A+++/A++
- Heat pump Nexus M8
- Buffer tank FISH S4 100X (100L)
- Domestic hot water tank FISH S15 300X (300L)
- Magnetic filter - Brass Term 1"
- 3-way valve 1"
- INSYG CLOUD with antenna (Internet control)
- Pump Grundfos UPM4L (K) PWN 25-75
- Safety valve SYR 1915 - 1" - 2.5 bar
- Mechanical heat meter SensoStar E
- Electricity meter Zamel LEM-30
- Pass-through sleeve - 1"
- Brass reducing tee - 1" x 1/2" x 1"
- Reducing piece for capillary 1/2"XM10 SF73-1/2"XM10
- Pump group GPO HYDRA DN 25
Circulation pump not integrated into the heat pump!
The heat pumps are equipped with a continuously variable compressor and a brushless fan with variable speed control. This allows the heat pump to adapt to the energy demand of the heat consumers. The stable operation of the heat pump enables high performance with low compressor noise. The refrigeration system equipped with EVI technology (Enhanced Vapour Injection) ensures high efficiency even with conventional radiator systems.
- One of the most cost-effective ways to heat buildings. The system also works at temperatures of -25°C
- High efficiency and long service life thanks to the use of components from world-renowned manufacturers
- Comprehensive control ensures optimal system control and protection. Internet control is possible. A wired control panel is standard equipment.
- High operating comfort. Intuitive and simple operation of the control system.
- The compact design of the unit allows for quick installation.
- Energy class A++ at 55°C flow temperature, A+++ at 35°C flow temperature
The highest level of comfort
NEXUS M EVI heat pumps enable optimal room temperature with minimal energy consumption. They allow for achieving the right air temperature while also providing access to hot water to fully meet consumer needs.
Advantages of monoblock design
The pump is designed entirely for outdoor installation. Characteristic of the pump is the fact that the entire cooling system is housed in a single unit and only the pipes that supply the building with heat are routed outside.
Operation under extreme conditions
NEXUS heat pumps are innovative system solutions from SUNEX that keep your home warm even at extremely low temperatures down to -25 degrees Celsius. In operation, they offer exceptional efficiency, reliability, and cost-effectiveness.
Operation under extreme conditions
NEXUS heat pumps are innovative system solutions from SUNEX that keep your home warm even at extremely low temperatures down to -25 degrees Celsius. In operation, they offer exceptional efficiency, reliability, and cost-effectiveness.
Technical data:
- SCOP (W35) moderate climate: 4.59 kWh
- SCOP (W55) moderate climate: 3.47 kWh
- Energy efficiency class (W35): A+++
- Energy efficiency class (W55): A++
- Compressor: Panasonic (rotating, multi-stage vapor injection)
- Expansion valve: electronic
- Number of fans: 1
- Circulation pump: no
- Water-side pressure loss: 31 kPa
- Control: Standard control module
- Outside temperature: -25 to +45°C
- Flow temperature: 55°C
- Recommended heating water flow: 1.4 m³/h
- Refrigerant / GWP: R32 / 675
- Amount of refrigerant R32: 1.3 kg
- Defrosting method: Hot gas (reverse cycle)
- Sound power level: 53 dB
- Dimensions: 970x475x835 mm
- Weight (net/gross): 110/120 kg
- Power supply: 220-240V 50Hz
- Max. current (heating/cooling/DHW): 8.30/9.67/9.45 A
Buffer tank FISH S4 100X as wall-mounted or freestanding version
The buffer tank is designed for vertical operation only. It is ideal for all types of heating systems, especially those operated with heat pumps. The buffer tank allows connection of a heat source circuit and a central heating circuit. The buffer tank can be wall-mounted or placed on feet. Buffer tanks can be used for storing cold water with a temperature of 7 to 12°C.
Technical data buffer tank FISH S4 100X:
- Material: S235JR
- Capacity: 100L
- Maximum operating pressure of the tank: 3bar
- Operating temperature range: 7÷95ºC
- Insulation: 30mm
- Heat source connection: G 1½”
- Water drain connection: G 1½”
- Temperature sensor connection: G ½”
- Weight: 23kg
Domestic hot water tank FISH S15 300X
Hot water tank in freestanding design for domestic hot water preparation. The tank has a large-surface heat exchanger for a heat pump. The contact surface of the hot water with the tank is protected against corrosion by a layer of high-quality enamel and a magnesium anode*. Complies with DIN 4753. This ensures that the domestic hot water only comes into contact with a hygienically clean surface.
Technical data hot water tank Fish S15 300X:
- Material: S235JR
- Capacity: 300L
- Welding: automatic welding
- Protection: high-quality enamel layer and protective anode
- Maximum operating pressure of the tank: 10 bar
- Maximum test pressure: 15 bar
- Maximum operating temperature: 95ºC
- Insulation: 50mm thick polyurethane foam
- Outer casing: grey color
- Heat exchanger: steel tube S235JR
- Inspection opening: ø125mm/ø180mm
Insyg Cloud + Antenna (Internet access and control)
The Insyg Cloud control module provides the manufacturer with remote access to your heat pump. Sunex handles the complete configuration and support of your heat pump.
The Insyg Cloud is used for the operation of the Sunex M EVI heat pump.
Advantages of Insyg Cloud:
- Internet access
- Fast response time
- Designed for NEXUS M EVI pumps
Pump group GPO HYDRA DN 25
Two-way pump group with Hydra GPO 25-6-130 without mixing valve ball valve DN 25
The two-way pump group with ball valve serves to force the circulation of the working medium in the central heating, process heat, and cooling system. It is equipped with two ball valves with thermometer, a circulation pump Hydra GPO 25-6-130, thermal insulation, and a ball valve with rotary knob.
The GPO 25-6-130 pump can be operated at a constant pump speed, which can be set on the control knob. In addition, it is also possible to control the pump speed depending on the characteristic curve Δp-V.
Hydra GPO is an electronic and energy-saving pump with high efficiency. The pump is designed for use in circuits filled with water or glycol solutions with a concentration of ≤50%.
Technical data:
- Dimensions (L x W x H) mm: 390 x 275 x 140
- Connection distance mm: 125
- Upper connections: 2 x IG 1"
- Lower connections: 2 x AG 1 1/2"
- Maximum pressure bar: 6
- Maximum temperature °C: 90
- Pump: Hydro GPO 25-6-130
- Voltage V, Hz: 1~230, 50 - 60
- Maximum current A: 0.5
- Energy efficiency index EEI ?: 0.20
- Power consumption max. W: 65
- Weight kg: approx. 5.3
- Model: DN 25
Technical data circulation pump:
- Liquid Temp.: 2°C~110°C
- Ambient Temp.: 0~+40°C
- Storage Temp.: -35°C~80°C
- Max. Pressure: 10bar
- Protection class: IP44
- Voltage/Frequency: 220V~240V, 50/60Hz
- Insulation class: E
- Maximum input power: 65W
- Pipe dimensions: DN25
- Connection distance: 130mm
- Max. head: 8m
- Connections: 1 1/2"
- 3 Max. flow rate: 4m/h
Important note!
The installation and commissioning of the devices must be carried out exclusively by specialist personnel. In the event of a complaint, professional installation/commissioning by qualified specialist companies (specialist contractor certificate and special qualification) must be proven. If no proof is provided, all guarantees and warranties will expire.
Technical changes and errors reserved! Subject to prior sale! Illustration similar!
Refrigerant leaks contribute to climate change. Refrigerants with a lower global warming potential (GWP) contribute less to global warming in the event of a leak than those with a higher global warming potential (GWP). A leak of 1 kg of this refrigerant would therefore have a greater impact on global warming than 1 kg of CO2 over a 100-year period, proportional to the refrigerant's GWP value. Do not perform any work on the refrigerant circuit or disassemble the unit – always consult qualified personnel.
SUNEX SA Ziegelweg 7 02906 Niesky Poland service@sunex-deutschland.de https://sunex-deutschland.de/