Skip to product information
1 of 9

Sunex

SUNEX FISH S15 X hot water storage tank, 200 to 500 liters | High-performance heat exchanger with large heating surface

SUNEX FISH S15 X hot water storage tank, 200 to 500 liters | High-performance heat exchanger with large heating surface

Energieeffizienzklasse für Kühlen Energieeffizienzklasse für Kühlen Energieeffizienzklasse für Kühlen Energieeffizienzklasse für Kühlen
Energieeffizienzklasse für Heizen Energieeffizienzklasse für Heizen Energieeffizienzklasse für Heizen Energieeffizienzklasse für Heizen
Regular price 829,00€
Regular price 829,00€ Sale price 959,00€
Sale Sold out

Price incl. VAT.

Selection

Delivery time on request

In stock

View full details

Product informations

"SUNEX FISH S15 X hot water storage tank, 200 to 500 liters | High-performance heat exchanger with large heating surface "

Data sheet Download PDF
Installation instructions Download PDF

SUNEX FISH S15 X hot water storage tank, 200 to 500 liters | High-performance heat exchanger with large heating surface | Domestic hot water storage tank for heat pumps

Hot water storage tanks - domestic hot water storage tanks for heat pumps in sizes of 200, 300, 400 and 500 liters

Vertical hot water storage tank for domestic hot water preparation. The tank features a large-surface heat exchanger for a heat pump. The contact surface between the hot water and the tank is protected against corrosion by a layer of high-quality enamel and a magnesium anode*. Complies with DIN 4753. This ensures that the domestic hot water only comes into contact with a hygienically clean surface.

Advantages of SUNEX hot water storage tanks

  • Constant hot water supply: The storage tank ensures that hot water is continuously available even when several taps are used simultaneously.
  • Efficient heat transfer: The FISH S15 storage tank is equipped with a large-surface heat exchanger that enables fast and efficient heat transfer – particularly useful in conjunction with heat pumps.
  • Compact design: Thanks to its compact dimensions, the storage unit can be easily installed even in small rooms.
  • Hygienically clean service water: High-quality materials and the DIN 4753 standards ensure a hygienically clean surface of the storage tank, making contact with the service water safe.
  • Flexible installation options: The hot water storage tank can be installed flexibly and adapts to the local conditions.
  • Durability: Robust construction and high-quality insulation ensure a long service life and reliable operation.
  • High comfort: The constant and reliable hot water supply maximizes everyday user comfort.


Thermal insulation


The thermal insulation in the storage tanks consists of a layer of CFC-free polyurethane rigid foam and a replaceable layer of PVC jacket.

Standard equipment

Inspection opening, thermometer, socket for electric heating element, magnesium anode*, internal large-area heat exchanger.

*Optionally, a titanium anode can be used.

  • Material: S235JR
  • Welding: automatic welding
  • Protection: high-quality enameling and sacrificial anode
  • Maximum operating pressure of the storage tank: 10 bar
  • Maximum test pressure: 15 bar
  • Maximum operating temperature: 95ºC
  • Insulation: 50 mm thick polyurethane foam
  • Outer shell: Grey color
  • Heat exchanger: Steel tube S235JR
  • Inspection opening: ø122mm/ø180mm


Technical data

1- High-quality enamel for reliable corrosion protection
2- Highly efficient heat exchanger with enlarged surface area for heat pumps
3 connection spigots for mounting a specially adapted UV-20 disinfection system
4. Inspection opening for easy cleaning,
5- PUR foam insulation for excellent thermal insulation

Important NOTE!

The installation and commissioning of the equipment must be carried out exclusively by qualified personnel. In the event of a complaint, proof of proper installation by qualified specialists (certificate of professional qualification and special qualifications) must be provided. If no such proof is provided, all warranties and guarantees will be void.

Technical specifications subject to change without notice. Errors and omissions excepted. Subject to prior sale. Image may differ from actual product.

Refrigerant leaks contribute to climate change. Refrigerants with a lower global warming potential (GWP) contribute less to global warming in the event of a leak than those with a higher GWP. A leak of 1 kg of this refrigerant would therefore have a greater impact on global warming, proportional to the refrigerant's GWP value, than 1 kg of CO2, over a period of one hundred years. Do not attempt any work on the refrigeration circuit or disassemble the unit – always consult qualified personnel.

SUNEX SA Ziegelweg 7 02906 Niesky Poland service@sunex-deutschland.de https://sunex-deutschland.de/

Do you have any questions about the product?

SUNEX FISH S15 X hot water storage tank, 200 to 500 liters | High-performance heat exchanger with large heating surface

By clicking "Send Message" you agree to the Privacy Policy & the Terms and Conditions of Clima-Air GmbH (klimango.de).